Technical Innovations: 45° Angle Cross
- The 3-point Insulation Displacement Connection (IDC) method of termination gives durable and long lasting connections. Insulation clamping ribs hold wires firmly in position and isolate the contact area from vibration and other forms of mechanical stress.
- Flexible silver-plated contacts, positioned at 45° angle across the axis of the wire, make a solid, gas tight connection.
- Constant axial and torsion restoring forces, created by the unique contract and plastic housing, sustains a durable connection.
Positioning the contacts at a 45°angle leaves more wire between contact points and provides a reliable, stress resistant connection.
Positioning contacts at a 90° angle produces a point of weakness subject to possible breakage.
Advantage:
- High-Efficiency IDC Technology: Krone modules utilize Insulation Displacement Connection (IDC), enabling tool-terminated, no-strip wiring for fast, error-free installations.
- Space-Saving & High Density: Compact design maximizes port density in racks (e.g., 19-inch frames), ideal for data centers with limited space. (Such as: NT Series is the most high density series)
- Superior Electrical Performance:
- Low insertion loss and crosstalk (supports Cat3 Cat5 Cat5e and Cat6). (e.g: Highband series can reach Cat5e, Cat6 Speed)
- Gas-tight connections ensure long-term stability and minimal oxidation.
- Cost-Effective & Future-Proof: Reduces labor/time costs and supports upgrades without overhauling infrastructure.
There are 4 types contact type which can used in different systems.
Type | Contact Image | Apperance Color | Features |
---|---|---|---|
Disconnection | ![]() ![]() |
Cover: Grey Body: White |
Disconnection Modules use a two piece contact (normally closed), with a convenient disconnection feature. By inserting a disconnect plug into a wire pair, you can temporarily or permanently disconnect the circuit. A Test Cord can be inserted into a pair to test each side look both ways of the circuit independently. This greatly accelerates fault identification. The centre contact point can also be used for monitoring or over voltage protection. |
Connection | ![]() ![]() |
Cover: Grey Body: Grey |
Connection Modules have a one piece contact providing a continuous link between permanent wiring and jumper wiring, giving provision for monitoring access and overvoltage protection |
Switching | ![]() ![]() |
Cover: Grey Body: White |
Switching Modules house individual contacts and hence the circuits are disconnected when idle. By inserting plugs, cords or over voltage protection, the circuits can be connected whennecessary |
Earthing | ![]() ![]() |
Cover: Grey Body: Red |
Depending on the version, the LSA-PLUS earth modules (connection contacts) permit the routing of up to 36 cable wires to one common electrical potential. Via a permanently connected, flexible earth line, the backmount frame or an earth terminal is connected to earth potential. |
Disconnection is most popular in the market.
- Back Mount Frame
- Profile Tube
- Printed Circuit Board (PCB)
The Protector Unit has the function of preventing damage to internal equipment and personal injury caused by Overvoltage and Overcurrent entering from external lines; It has an alarm function and emits audible and visible signals when an alarm is triggered.
1 Pair Protector Unit (With Led)
1 Pair Protector Unit (Without Led)
Tips: Many projects in practice DO NOT require illuminated protector unit—as the project donot install MDF column alarms and MDF main alarms for visual signaling, also the cabinet room is not big, which is easy to find the issue point.
The Protection Magazine: refers to the overall protection module on the main distribution frame (MDF), which integrates multiple protector Unit and is used to centrally manage the over-voltage protection of communication lines
3 Pole 10 Pairs Protection Magazine for LSA-Plus Module
10 Pairs Protection Magazine for 10 Pairs NT Series Module (High Density Series) (Remarks: this protection magazine can be Overvoltage & Overcurrent Protection)
Parameter | Protection Magazine (2 Pole / 3 Pole) | Protection Unit |
---|---|---|
Capacity | 5 Pairs/8 Pairs/10 Pairs | Single-line protection |
Connection Type | Modular plug-in design | Modular plug-in design |
Feature | Overvoltage Protection 230V/350V | Overvoltage & Overcurrent Protection |
Grounding Bar | No Need Grounding Bar | Yes, need to assemble with Grounding bar If unit with led light, it need signal wire and signal line |
From an economic/budgetary perspective, 3 Pole 10 Pairs Protection Magazine offers a more cost-effective solution. However, the final decision should ultimately align with the project's functional requirements, as overvoltage and overcurrent protection must be comprehensively addressed to ensure system reliability and safety. |
1 Way=10 Pairs, 2 Way=20 Pairs, 3 Way=30 Pairs can customize the Capacity
Also can provide for 5 Pairs and 8 Pairs Module as well
Such as
- 1 Way=5 Pairs, 2 Way=10 Pairs, 3 Way=15 Pairs can customize the Capacity
- 1 Way=8 Pairs, 2 Way=16Pairs, 3 Way=24 Pairs can customize the Capacity
Nowadays, 5 Pairs and 8 Pairs Module use NOT TOO MUCH.
If SMALL Quantity, we recommend to use 10 Pairs Krone Type Module to instead of.
If Large Quantity, 5 Pairs & 8 Pairs Module will be cheaper then 10 Pairs Connection Module
19 Inch Rack Mount Type, have different capacity
Height 1U can fit following capacity:
- 20 Pairs
- 30 Pairs
- 40 Pairs
- 60 Pairs
- 90 Pairs
Height: 3U:
- 100 Pairs
- 150 Pairs
Based on rack mount shape, it have 2 types:
- Recessed Type
- Un-Recessed Type
Have:
- 10 Pairs
- 20 Pairs
- 30 Pairs
- 50 Pairs
- 100 Pairs
Also with 1 position for label holder
Material: SS304
200 Pairs or Customized
Label Holder for 10 Pair Module (Can Directly Install into 10 Pairs LSA Plus Module)
Have 2 Color:
1) Grey
2) Transaprent
100 Pairs Label Holder (Install on the back mount type frame)
Directly mounted on to the Back Mount Frame. Fixing on the first or last position on the BMF is recommended.
General each 100 pairs LSA Plus Module put 1 piece 100 Pairs Label Holder
100 Pairs Label Holder-Profile Type (Can used on Profile Tube Mount)
10 Pairs Label Holder-Profile Type (Can used on Profile Tube Mount)
Frequently Asked Questions
Q: Why too much different price for 10 pairs disconnection module in the market
A: General we sold ABS without flame retardant + Phosphor Bronze
There are different material for this products for your reference.
For Housing, there are 4 material level in the market
- PBT with flame retardant
- ABS with flame retardant
- ABS without flame retardant
- ABS recycled Material
For contact, there are 3 materials level in the market
- Best-Phosphor Bronze
- General-Brass
- Bad-Iron
If use with protector, only can use Phosphor Bronze, if use Brass and Iron the connection will be very bad
Q: Selection for humid environments?
A: Choose nickel-plated +Silver Plating contacts, we have many experience in sell humid environment